Autoclaves
Bacti-cinerator Sterilizer, BCS-I, BCS-II
- Sterilization Port Diameter: φ36 mm, φ22 mm
- Heating Zone Depth: 8.5 cm, 15.2 cm
- Heating Time to Max Temperature: 15 mins
- Rapid 2-second sterilization at 930°C
Autoclave, Class N ,Vertical Type, STV-AI Series
- Digital displayed automatic type
- Chamber volume: 35L, 50L, 75L, 100L
- Sterilization temperature: 116~134ºC
- Design pressure: 0.25 Mpa
- Automatic protection function
Class B Autoclave, STB-BB Series
- Table top Class B Autoclave
- Chamber volume: 8L, 12L, 18L, 23L
- Sterilization temperature: 134℃
- Design pressure: 0.25 Mpa
- Open-type top water tank
- 3 pulsating vacuum, Multiple test function
- Built-in steam generator
Class N Autoclave, STV-FL Series
- Volume: 30L, 50L, 75L
- Setting Range: 50~134℃
- Time Setting Range: 1~999min
- Rated Working Pressure: 0.217MPa
Autoclave, Class B, Benchtop Type, STB-BZ Series
- Automatic door switch
- Chamber volume: 18L, 23L, 45L
- Design temperature: 139℃
- Design pressure: 0.25 Mpa
- 3 pulsating vacuum, Multiple test function
- Built-in steam generator
Autoclave, Class N, Horizontal Type, STH-ND Series
- Horizontal type, Jacket structure
- Chamber volume: 150L,200L, 300L, 400L
- Working temperature: 105-138℃
- Working pressure: 0.245 Mpa
- Can set multiple sterilization programs
- Multiple safety protection
Portable Pressure Steam Sterilizer, STP-A Series
- Electric or LPG heating type
- Chamber volume: 18L, 24L
- Working temperature: 126ºC
- Working pressure: 0.142 Mpa
- Auto release when over pressure
Hydrogen Peroxide Plasma Sterilizer, STV Series
- Chamber Volume: 108L, 135L, 192L
- Working temperature: 40-60 ℃
- Total Cycle Time: 35-55 minutes
- Hydrogen peroxide concentration: 58%~60%
Hot Air Sterilizer, DOF-HAS-A Series
- Capacity: 34L, 57L, 70L, 138L, 188L
- Temperature range: RT+10-250 ℃
-
Safety device: Leakage protector/Over - temperature alarm
Bacti-cinerator Sterilizer, BCS-800A
- The Center High-temperature: 825℃±25℃
- The total length of heating area: 140mm
- Max. outer diameter: 15mm
-
Heating Time is 15 mins, the fastest can reach 5-7 seconds
Cassette Autoclave, STC-6000
- Sterilization Volume: 6 L
- The whole sterilization process is about 9 minutes
- Temperature range: 135 ° C- 138° C
- Maximum Operating Pressure: 242 kPa
Glass Bead Sterilizer, BGS-300L
- Digital control, up to 300℃
- Bead Capacity: 150g
- Heating Time: 25min(RT.to300c)
- Temp accuracy: 土5℃
Class N Autoclave, STV-ML Series
- Volume: 40L, 60L, 80L
- Setting Range: 50~134℃
- Time Setting Range: 1~999min
- Rated Working Pressure: 217MPa
Autoclave Sterilizer, Class N Autoclave, STV-I Series
- Class N autoclave sterilizer, vertical type
- volume: 35L, 50L, 75L, 100L,120L, 150L
- Bolted digital display automatic control
- Sterilization temperature: 116~134ºC
- Design pressure: 0.25 Mpa
- Automatic protection function
Autoclave, Class N, Horizontal Type, STH Series
- Sterilizing Volume: 150L, 200L, 280L, 400L, 500L
- Temp Range: 105℃ - 134℃
- Working Pressure: 0.22MPa
- Time of sterilization and drying: 0-60 min
- Equipped with drying function
Class B Autoclave, STB-APV35DV, STB-APV50DV
- Volume: 35L, 50L
- Temperature Range: 105~134℃
- Working Temperature: 138℃
- Timing Range: 0~99min