Biosafety Cabinets


Product

Class II Type A2 Biosafety Cabinets, BSC-IIA2-4J

  • Classification: Class II Type A2
  • Cleanliness level: ISO level 4
  • Filters: ULPA(U15)*2pcs
  • Vertical laminar negative pressure model
  • Working zone area: 1300*520*640 mm
Product

Class II Type A2 Biological Safety Cabinets, BSC-IIA2 Series

  • Opening: 480mm
  • Inflow Air Velocity: 0.53±0.025m/s
  • Down flow Air Velocity: 0.33±0.025m/s
Product

Class II Type A2 Biological Safety Cabinets, BSC-IIA2-700

  • Work Surface Height: 770mm
  • Opening Height: 350mm
  • Inflow Air Velocity: 230m³/h (135cfm)
  • Down flow Air Velocity: 428m³/h (252cfm)
Product

Class II Type B2 Biological Safety Cabinets, BSC-IIB2 Series

  • Opening: 480mm
  • Inflow Air Velocity: 0.53±0.025m/s
  • Down flow Air Velocity: 0.33±0.025m/s
Product

Class II Type A2 Biosafety Cabinets, BSC-IIA2-2J

  • Classification: Class II Type A2
  • Filters: ULPA(U15)*2pcs
  • Working zone area: 600*500*520 mm
  • Unique negative pressure leak-proof design
  • Equipped with height limit alarm device
  • Front window and germicidal lamp interlocking design
Product

Class II Type A2 Biosafety Cabinets, BSC-IIA2-3J

  • Classification: Class II Type A2
  • Cleanliness level: ISO level 4
  • Filters: ULPA(U15)*2pcs
  • Air flow mode: 30% discharge, 70% internal circulation
  • Vertical laminar negative pressure model
  • Working zone size: 1000*520*640 mm
Product

Class II Type A2 Biosafety Cabinets, BSC-IIA2-5J

  • Classification: Class II Type A2
  • Cleanliness level: ISO level 4
  • Filters: ULPA(U15)*2pcs
  • Air flow mode: 30% discharge, 70% internal circulation
  • Vertical laminar negative pressure model
  • Working zone area: 1600*520*640 mm
Product

Class II Type B2 Biosafety Cabinets, BSC-IIB2-3J

  • Classification: Class II Type B2
  • Cleanliness level: ISO level 4
  • Filters: ULPA(U15)*2pcs
  • Air flow mode: 100% discharge, 0 internal circulation
  • Vertical laminar negative pressure model
  • Working zone size: 1000*520*640 mm
Product

Class II Type B2 Biosafety Cabinets, BSC-IIB2-4J

  • Classification: Class II Type B2
  • Cleanliness level: ISO level 4
  • Filters: ULPA(U15)*2pcs
  • Air flow mode: 100% discharge, 0 cycle requirement
  • Working zone size: 1300*520*640 mm
Product

Class II Type B2 Biosafety Cabinets, BSC-IIB2-5J

  • Classification: Class II Type B2
  • Cleanliness level: ISO level 4
  • Filters: ULPA(U15)*2pcs
  • Air flow mode: 100% discharge, 0 internal circulation
  • Vertical laminar negative pressure model
  • Working zone size: 1600*520*640mm